{"id":3507,"date":"2025-08-12T07:45:53","date_gmt":"2025-08-12T06:45:53","guid":{"rendered":"https:\/\/metisengineering.com\/?p=3507"},"modified":"2025-12-18T06:34:37","modified_gmt":"2025-12-18T06:34:37","slug":"thermal-runaway-in-lithium-ion-batteries","status":"publish","type":"post","link":"https:\/\/metisengineering.com\/pl\/thermal-runaway-in-lithium-ion-batteries\/","title":{"rendered":"Wczesne wykrywanie ucieczki termicznej w akumulatorach litowo-jonowych za pomoc\u0105 czujnika Cell Guard firmy Metis Engineering"},"content":{"rendered":"<h2 data-pm-slice=\"1 1 []\">Wczesne wykrywanie ucieczki termicznej w akumulatorach litowo-jonowych za pomoc\u0105 czujnika Cell Guard firmy Metis Engineering<\/h2>\n<p>Rozbieg termiczny (TR) jest jednym z najwa\u017cniejszych wyzwa\u0144 w zakresie bezpiecze\u0144stwa, przed kt\u00f3rymi stoj\u0105 obecnie systemy akumulator\u00f3w litowo-jonowych (Li-ion). Odnosi si\u0119 on do samoprzyspieszaj\u0105cej si\u0119 reakcji egzotermicznej, w kt\u00f3rej, gdy dochodzi do niekontrolowanego wzrostu temperatury, rosn\u0105ca temperatura wewn\u0119trzna wyzwala dalsze reakcje chemiczne, wytwarzanie ciep\u0142a, uwalnianie gazu, a w ci\u0119\u017ckich przypadkach po\u017car lub wybuch. Sekwencja ta mo\u017ce szybko eskalowa\u0107, prowadz\u0105c do produkcji \u0142atwopalnych gaz\u00f3w i pozostawiaj\u0105c niewiele czasu na interwencj\u0119. Poniewa\u017c akumulatory litowo-jonowe nadal zasilaj\u0105 pojazdy elektryczne (EV), magazyny energii na skal\u0119 sieciow\u0105, statki morskie i systemy lotnicze, zdolno\u015b\u0107 do wykrywania i reagowania na wczesne etapy niekontrolowanego wzrostu temperatury staje si\u0119 niezb\u0119dna dla bezpiecze\u0144stwa, niezawodno\u015bci i zgodno\u015bci z przepisami.<\/p>\n<p>Metis Engineering's <strong>Cell Guard<\/strong> Czujnik bezpiecze\u0144stwa baterii VOC oferuje wysoce skuteczne rozwi\u0105zanie wczesnego ostrzegania. Wykrywaj\u0105c lotne zwi\u0105zki organiczne (VOC) emitowane podczas najwcze\u015bniejszych etap\u00f3w awarii ogniwa spowodowanych wadami produkcyjnymi, zapewnia cenne okno interwencyjne. Umo\u017cliwia to operatorom podj\u0119cie dzia\u0142a\u0144 naprawczych w celu zapobie\u017cenia niekontrolowanemu wzrostowi temperatury, zanim w pe\u0142ni si\u0119 rozwinie, potencjalnie zapobiegaj\u0105c katastrofalnym uszkodzeniom, utracie aktyw\u00f3w i uwolnieniu toksycznych gaz\u00f3w.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-3534 aligncenter\" src=\"https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-300x209.jpg\" alt=\"\" width=\"300\" height=\"209\" srcset=\"https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-300x209.jpg 300w, https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-1024x713.jpg 1024w, https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-768x535.jpg 768w, https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-1536x1069.jpg 1536w, https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-2048x1425.jpg 2048w, https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-18x12.jpg 18w, https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-1000x696.jpg 1000w, https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-64x45.jpg 64w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<h3>Zrozumienie ucieczki termicznej i jej prekursor\u00f3w<\/h3>\n<p>Ucieczka termiczna w ogniwie akumulatora litowo-jonowego zazwyczaj przebiega zgodnie z sekwencj\u0105 reakcji \u0142a\u0144cuchowej. Nadu\u017cycia wewn\u0119trzne lub zewn\u0119trzne, takie jak prze\u0142adowanie, przegrzanie, zwarcia lub uszkodzenia mechaniczne, mog\u0105 zagrozi\u0107 interfazie elektrolitu sta\u0142ego (SEI) lub separatorowi. Ta degradacja, cz\u0119sto wynikaj\u0105ca z uszkodze\u0144 fizycznych, inicjuje rozk\u0142ad elektrolitu, kt\u00f3ry mo\u017ce wytwarza\u0107 ciep\u0142o i gazy wewn\u0105trz ogniwa. Je\u015bli nie jest to kontrolowane, nagromadzenie ciep\u0142a i ci\u015bnienia mo\u017ce doprowadzi\u0107 ogniwo do niekontrolowanego wzrostu temperatury, cz\u0119sto powoduj\u0105c awari\u0119 s\u0105siednich ogniw.<\/p>\n<p>Gdy rozpocznie si\u0119 rozprzestrzenianie, ryzyko dla pakietu i jego otoczenia wzrasta wyk\u0142adniczo. W pojazdach elektrycznych mo\u017ce to doprowadzi\u0107 do rozprzestrzenienia si\u0119 po\u017caru w ca\u0142ym poje\u017adzie; w stacjonarnych magazynach mo\u017ce to spowodowa\u0107 uszkodzenie obiektu na du\u017c\u0105 skal\u0119. Zapobieganie tej sekwencji wymaga wykrywania najwcze\u015bniejszych, najbardziej subtelnych oznak awarii - na d\u0142ugo przed pojawieniem si\u0119 konwencjonalnych znak\u00f3w ostrzegawczych.<\/p>\n<h3>Dlaczego konwencjonalny monitoring cz\u0119sto zawodzi<\/h3>\n<p>Tradycyjne systemy zarz\u0105dzania akumulatorami (BMS) koncentruj\u0105 si\u0119 na monitorowaniu temperatury, napi\u0119cia i stanu na\u0142adowania. Chocia\u017c s\u0105 to istotne parametry dla r\u00f3\u017cnych typ\u00f3w akumulator\u00f3w, cz\u0119sto pozostaj\u0105 one stabilne a\u017c do momentu przed lub w trakcie katastrofalnej awarii. Oznacza to, \u017ce zanim system BMS wykryje wzrost temperatury akumulatora lub spadek napi\u0119cia, mo\u017cliwo\u015b\u0107 podj\u0119cia dzia\u0142a\u0144 zapobiegawczych jest ju\u017c ograniczona do sekund, a nie minut.<\/p>\n<p>Ta luka w mo\u017cliwo\u015bciach wykrywania jest kluczowym powodem, dla kt\u00f3rego po\u017cary akumulator\u00f3w w pojazdach elektrycznych lub magazynach mog\u0105 szybko eskalowa\u0107. Zlikwidowanie tej luki wymaga zidentyfikowania sygna\u0142u prekursorowego, kt\u00f3ry pojawia si\u0119 wcze\u015bniej w sekwencji awarii, czego\u015b, co zapewnia wyra\u017ane i wymierne ostrze\u017cenie dla bezpiecze\u0144stwa przeciwpo\u017carowego.<\/p>\n<h3>LZO: Najwcze\u015bniejszy wykrywalny znak ostrzegawczy<\/h3>\n<p>Badania, w tym badania opublikowane w <em>Journal of The Electrochemical Society<\/em> i Sandia National Laboratories, potwierdzaj\u0105, \u017ce jednym z najwcze\u015bniejszych wykrywalnych objaw\u00f3w zbli\u017caj\u0105cej si\u0119 awarii ogniwa jest uwalnianie lotnych zwi\u0105zk\u00f3w organicznych wewn\u0105trz akumulatora. Te \u0142atwopalne gazy - takie jak w\u0119glan etylenu i w\u0119glan dietylu - s\u0105 generowane, gdy elektrolit zaczyna si\u0119 rozk\u0142ada\u0107 podczas odpowietrzania ogniwa, cz\u0119sto powoduj\u0105c nadmierne ciep\u0142o i kilka minut przed skokiem temperatury zwi\u0105zanym z niekontrolowanym wzrostem temperatury.<\/p>\n<p>Poniewa\u017c lotne zwi\u0105zki organiczne pojawiaj\u0105 si\u0119 na etapie odpowietrzania gazu, ich wykrycie daje wyj\u0105tkow\u0105 mo\u017cliwo\u015b\u0107 dzia\u0142ania, zanim temperatura wewn\u0119trzna przekroczy krytyczny pr\u00f3g 150-200\u00b0C, co mo\u017ce prowadzi\u0107 do ekstremalnie wysokich temperatur, w kt\u00f3rych ucieczka jest prawie nieunikniona.<\/p>\n<h3>Rozwi\u0105zanie Metis Engineering Cell Guard<\/h3>\n<p>Metis Engineering's <strong>Cell Guard<\/strong> zosta\u0142 specjalnie zaprojektowany do wykrywania \u015bladowych emisji LZO w st\u0119\u017ceniach tak niskich jak cz\u0119\u015bci na miliard. Zainstalowany wewn\u0105trz obudowy akumulatora, czujnik w spos\u00f3b ci\u0105g\u0142y pobiera pr\u00f3bki wewn\u0119trznej atmosfery, analizuj\u0105c je w czasie rzeczywistym. System komunikuje si\u0119 za po\u015brednictwem interfejsu CAN, umo\u017cliwiaj\u0105c p\u0142ynn\u0105 integracj\u0119 z systemem BMS i umo\u017cliwiaj\u0105c natychmiastowe automatyczne reakcje.<\/p>\n<p>Opr\u00f3cz wykrywania VOC, Cell Guard monitoruje r\u00f3wnie\u017c punkt rosy, wilgotno\u015b\u0107, poziom wodoru i obci\u0105\u017cenia udarowe. Ta wieloparametrowa funkcja zapewnia kompleksowy wgl\u0105d w stan pakietu, wspieraj\u0105c zar\u00f3wno strategie bezpiecze\u0144stwa, jak i konserwacji predykcyjnej.<\/p>\n<h3>Tworzenie krytycznego okna interwencji<\/h3>\n<p>Testy na poziomie opakowania pokazuj\u0105, \u017ce Cell Guard mo\u017ce wykrywa\u0107 emisje LZO <strong>7-17 minut<\/strong> przed wyst\u0105pieniem niekontrolowanego wzrostu temperatury. To okno wczesnego ostrzegania ma kluczowe znaczenie, poniewa\u017c mo\u017ce zapobiega\u0107 sytuacjom, w kt\u00f3rych dochodzi do niekontrolowanego wzrostu temperatury. Integracja z systemem zarz\u0105dzania akumulatorem pozwala na szereg interwencji, w tym:<\/p>\n<ul>\n<li>Odci\u0119cie obci\u0105\u017cenia elektrycznego uszkodzonego pakietu, zatrzymanie cykli \u0142adowania i roz\u0142adowania, aby ogniwa mog\u0142y si\u0119 pasywnie sch\u0142odzi\u0107.<\/li>\n<li>Odizolowanie uszkodzonego modu\u0142u od reszty zestawu, aby zapobiec rozprzestrzenianiu si\u0119 ciep\u0142a.<\/li>\n<li>Aktywacja system\u00f3w zarz\u0105dzania temperatur\u0105, takich jak wentylatory lub p\u0119tle ch\u0142odziwa, w celu rozproszenia ciep\u0142a.<\/li>\n<li>Uruchamianie system\u00f3w przeciwpo\u017carowych - takich jak aerozole, gazy oboj\u0119tne lub \u015brodki p\u0142ynne - przed zap\u0142onem.<\/li>\n<\/ul>\n<p>Podejmuj\u0105c te dzia\u0142ania na etapie odpowietrzania gazu, operatorzy mog\u0105 op\u00f3\u017ani\u0107 lub nawet ca\u0142kowicie zapobiec sekwencji niekontrolowanego wzrostu temperatury.<\/p>\n<h3>Jak Cell Guard wypada na tle innych narz\u0119dzi diagnostycznych<\/h3>\n<p>Podczas gdy elektrochemiczna spektroskopia impedancyjna (EIS) mo\u017ce r\u00f3wnie\u017c wykrywa\u0107 wczesn\u0105 degradacj\u0119 ogniw, jest ona bardziej z\u0142o\u017cona i mniej odpowiednia do monitorowania in-situ, w czasie rzeczywistym, zw\u0142aszcza w przypadku du\u017cych pakiet\u00f3w o du\u017cej pojemno\u015bci. Na pomiary EIS mo\u017ce mie\u0107 wp\u0142yw architektura pakietu i wysokie temperatury, podczas gdy wewn\u0119trzne warunki zwarcia w ogniwach litowo-jonowych wymagaj\u0105 kontrolowanych warunk\u00f3w testowych. Z kolei czujniki VOC, takie jak Cell Guard, nie s\u0105 zale\u017cne od wielko\u015bci lub z\u0142o\u017cono\u015bci pakietu i dostarczaj\u0105 szybki, niezawodny sygna\u0142, na kt\u00f3ry mo\u017cna natychmiast zareagowa\u0107.<\/p>\n<p>Inne czujniki gazu mog\u0105 nie by\u0107 wystarczaj\u0105co czu\u0142e, aby wykrywa\u0107 LZO w tak niskich st\u0119\u017ceniach lub mog\u0105 nie by\u0107 zaprojektowane do trudnych warunk\u00f3w wewn\u0119trznych pakietu litowo-jonowego. Ma\u0142a, solidna obudowa Cell Guard umo\u017cliwia instalacj\u0119 w pobli\u017cu ogniw w celu uzyskania maksymalnej dok\u0142adno\u015bci, zapewniaj\u0105c bezpieczn\u0105 prac\u0119 bez uszczerbku dla trwa\u0142o\u015bci.<\/p>\n<h3>Implikacje regulacyjne i bran\u017cowe<\/h3>\n<p>Globalne standardy bezpiecze\u0144stwa, takie jak ISO 6469, UN ECE R100 i UL 2580, k\u0142ad\u0105 wi\u0119kszy nacisk na wczesne wykrywanie usterek w systemach akumulator\u00f3w litowo-jonowych. Wdro\u017cenie wczesnego wykrywania LZO w systemach magazynowania energii bezpo\u015brednio wspiera zgodno\u015b\u0107 z tymi normami. Dla producent\u00f3w stanowi to r\u00f3wnie\u017c przewag\u0119 konkurencyjn\u0105, demonstruj\u0105c proaktywne \u015brodki bezpiecze\u0144stwa organom regulacyjnym, ubezpieczycielom i klientom.<\/p>\n<p>Ponadto bran\u017ca ubezpieczeniowa coraz cz\u0119\u015bciej uznaje, \u017ce systemy wczesnego wykrywania mog\u0105 zmniejszy\u0107 liczb\u0119 roszcze\u0144 zwi\u0105zanych z incydentami ucieczki termicznej. Wdro\u017cenie wykrywania LZO mo\u017ce pom\u00f3c operatorom uzyska\u0107 ni\u017csze sk\u0142adki i korzystniejsze warunki, poniewa\u017c mo\u017ce r\u00f3wnie\u017c pom\u00f3c w unikni\u0119ciu ucieczki termicznej.<\/p>\n<h3>Zastosowania wykraczaj\u0105ce poza pojazdy elektryczne<\/h3>\n<p>Korzy\u015bci p\u0142yn\u0105ce z wczesnego wykrywania niekontrolowanego wzrostu temperatury wykraczaj\u0105 daleko poza pojazdy elektryczne. W stacjonarnych magazynach energii wykrycie uszkodzonego ogniwa przed zap\u0142onem mo\u017ce zapobiec wielomegawatowym po\u017carom akumulator\u00f3w litowo-jonowych, zw\u0142aszcza \u017ce ryzyko niekontrolowanego wzrostu temperatury wzrasta. W zastosowaniach lotniczych, gdzie ewakuacja nie zawsze jest mo\u017cliwa, wykrywanie LZO zapewnia istotn\u0105 nadmiarowo\u015b\u0107. Operatorzy morscy mog\u0105 zintegrowa\u0107 system z platformami morskimi lub statkami, gdzie dost\u0119p do zasob\u00f3w przeciwpo\u017carowych jest ograniczony.<\/p>\n<p>Nawet w zastosowaniach z bateriami drugiej generacji, gdzie starzej\u0105ce si\u0119 ogniwa stanowi\u0105 nieprzewidywalne ryzyko, Cell Guard mo\u017ce monitorowa\u0107 poziomy LZO w czasie rzeczywistym w pojedynczym zestawie baterii, umo\u017cliwiaj\u0105c operatorom usuni\u0119cie podejrzanych modu\u0142\u00f3w, zanim zagro\u017c\u0105 one bezpiecze\u0144stwu systemu.<\/p>\n<h3>Budowanie bezpieczniejszej przysz\u0142o\u015bci akumulator\u00f3w<\/h3>\n<p>W miar\u0119 jak wi\u0119kszo\u015b\u0107 akumulator\u00f3w litowo-jonowych staje si\u0119 coraz wi\u0119ksza i bardziej energoch\u0142onna, konsekwencje niekontrolowanego wzrostu temperatury, w tym samozniszczenia, staj\u0105 si\u0119 coraz powa\u017cniejsze. Tradycyjne metody monitorowania nie s\u0105 w stanie zagwarantowa\u0107 wystarczaj\u0105cego ostrze\u017cenia. Cell Guard firmy Metis Engineering wype\u0142nia t\u0119 krytyczn\u0105 luk\u0119 w bezpiecze\u0144stwie, wykrywaj\u0105c emisje LZO wystarczaj\u0105co wcze\u015bnie, aby podj\u0105\u0107 skuteczne dzia\u0142ania.<\/p>\n<p>Zapewniaj\u0105c wielominutowe okno interwencji, Cell Guard umo\u017cliwia systemom wy\u0142\u0105czanie, ch\u0142odzenie lub izolowanie uszkodzonych ogniw baterii, nawet zapobiegaj\u0105c eskalacji do pe\u0142nego niekontrolowanego wzrostu temperatury - po\u017caru. Chroni to zasoby, wyd\u0142u\u017ca \u017cywotno\u015b\u0107 baterii, poprawia zgodno\u015b\u0107 z przepisami i zwi\u0119ksza zaufanie publiczne do zelektryfikowanego transportu i magazynowania energii.<\/p>\n<p>W wy\u015bcigu maj\u0105cym na celu uczynienie akumulator\u00f3w bezpieczniejszymi, inteligentniejszymi i bardziej odpornymi, wczesne wykrywanie niekontrolowanego wzrostu temperatury jest nie tylko zalet\u0105 technologiczn\u0105 - jest konieczno\u015bci\u0105.<\/p>","protected":false},"excerpt":{"rendered":"<p>Early detection of Thermal Runaway in Lithium-Ion batteries using Metis Engineering\u2019s Cell Guard sensor Thermal runaway (TR) is one of the most critical safety challenges [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":3534,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[226],"tags":[],"class_list":["post-3507","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-reference"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Thermal Runaway in Lithium-Ion batteries - Metis Engineering<\/title>\n<meta name=\"description\" content=\"Early detection of Thermal Runaway in Lithium-Ion batteries using Metis Engineering\u2019s Cell Guard sensor Thermal runaway (TR) is one of the most critical\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/metisengineering.com\/pl\/thermal-runaway-in-lithium-ion-batteries\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Thermal Runaway in Lithium-Ion batteries - Metis Engineering\" \/>\n<meta property=\"og:description\" content=\"Early detection of Thermal Runaway in Lithium-Ion batteries using Metis Engineering\u2019s Cell Guard sensor Thermal runaway (TR) is one of the most critical\" \/>\n<meta property=\"og:url\" content=\"https:\/\/metisengineering.com\/pl\/thermal-runaway-in-lithium-ion-batteries\/\" \/>\n<meta property=\"og:site_name\" content=\"Metis Engineering\" \/>\n<meta property=\"article:published_time\" content=\"2025-08-12T06:45:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-18T06:34:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1782\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Lukasz\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Napisane przez\" \/>\n\t<meta name=\"twitter:data1\" content=\"Lukasz\" \/>\n\t<meta name=\"twitter:label2\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/\"},\"author\":{\"name\":\"Lukasz\",\"@id\":\"https:\\\/\\\/metisengineering.com\\\/#\\\/schema\\\/person\\\/6b885e54b520c8d41752069c93f067ae\"},\"headline\":\"Early detection of Thermal Runaway in Lithium-Ion batteries using Metis Engineering\u2019s Cell Guard sensor\",\"datePublished\":\"2025-08-12T06:45:53+00:00\",\"dateModified\":\"2025-12-18T06:34:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/\"},\"wordCount\":1277,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/metisengineering.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/metisengineering.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/METIS_MAY_2023_004-scaled.jpg\",\"articleSection\":[\"Reference\"],\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/\",\"url\":\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/\",\"name\":\"Thermal Runaway in Lithium-Ion batteries - Metis Engineering\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/metisengineering.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/metisengineering.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/METIS_MAY_2023_004-scaled.jpg\",\"datePublished\":\"2025-08-12T06:45:53+00:00\",\"dateModified\":\"2025-12-18T06:34:37+00:00\",\"description\":\"Early detection of Thermal Runaway in Lithium-Ion batteries using Metis Engineering\u2019s Cell Guard sensor Thermal runaway (TR) is one of the most critical\",\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/metisengineering.com\\\/thermal-runaway-in-lithium-ion-batteries\\\/#primaryimage\",\"url\":\"https:\\\/\\\/metisengineering.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/METIS_MAY_2023_004-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/metisengineering.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/METIS_MAY_2023_004-scaled.jpg\",\"width\":2560,\"height\":1782,\"caption\":\"Battery destruction. 22 May 2023\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/metisengineering.com\\\/#website\",\"url\":\"https:\\\/\\\/metisengineering.com\\\/\",\"name\":\"Metis Engineering\",\"description\":\"Sensing The Future\",\"publisher\":{\"@id\":\"https:\\\/\\\/metisengineering.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/metisengineering.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/metisengineering.com\\\/#organization\",\"name\":\"Metis Engineering\",\"url\":\"https:\\\/\\\/metisengineering.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/metisengineering.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/metisengineering.com\\\/wp-content\\\/uploads\\\/2024\\\/06\\\/metis-logo-240.png\",\"contentUrl\":\"https:\\\/\\\/metisengineering.com\\\/wp-content\\\/uploads\\\/2024\\\/06\\\/metis-logo-240.png\",\"width\":240,\"height\":95,\"caption\":\"Metis Engineering\"},\"image\":{\"@id\":\"https:\\\/\\\/metisengineering.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/metisengineering.com\\\/#\\\/schema\\\/person\\\/6b885e54b520c8d41752069c93f067ae\",\"name\":\"Lukasz\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/55d18e132c3d0d63f7cd047da2d2a7f805a3392a84a615be5d6dca867281758e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/55d18e132c3d0d63f7cd047da2d2a7f805a3392a84a615be5d6dca867281758e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/55d18e132c3d0d63f7cd047da2d2a7f805a3392a84a615be5d6dca867281758e?s=96&d=mm&r=g\",\"caption\":\"Lukasz\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ucieczka termiczna w bateriach litowo-jonowych - Metis Engineering","description":"Wczesne wykrywanie niekontrolowanego wzrostu temperatury w akumulatorach litowo-jonowych za pomoc\u0105 czujnika Cell Guard firmy Metis Engineering Niekontrolowany wzrost temperatury (TR) jest jednym z najbardziej krytycznych zjawisk w akumulatorach litowo-jonowych.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/metisengineering.com\/pl\/thermal-runaway-in-lithium-ion-batteries\/","og_locale":"pl_PL","og_type":"article","og_title":"Thermal Runaway in Lithium-Ion batteries - Metis Engineering","og_description":"Early detection of Thermal Runaway in Lithium-Ion batteries using Metis Engineering\u2019s Cell Guard sensor Thermal runaway (TR) is one of the most critical","og_url":"https:\/\/metisengineering.com\/pl\/thermal-runaway-in-lithium-ion-batteries\/","og_site_name":"Metis Engineering","article_published_time":"2025-08-12T06:45:53+00:00","article_modified_time":"2025-12-18T06:34:37+00:00","og_image":[{"width":2560,"height":1782,"url":"https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-scaled.jpg","type":"image\/jpeg"}],"author":"Lukasz","twitter_card":"summary_large_image","twitter_misc":{"Napisane przez":"Lukasz","Szacowany czas czytania":"6 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/#article","isPartOf":{"@id":"https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/"},"author":{"name":"Lukasz","@id":"https:\/\/metisengineering.com\/#\/schema\/person\/6b885e54b520c8d41752069c93f067ae"},"headline":"Early detection of Thermal Runaway in Lithium-Ion batteries using Metis Engineering\u2019s Cell Guard sensor","datePublished":"2025-08-12T06:45:53+00:00","dateModified":"2025-12-18T06:34:37+00:00","mainEntityOfPage":{"@id":"https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/"},"wordCount":1277,"commentCount":0,"publisher":{"@id":"https:\/\/metisengineering.com\/#organization"},"image":{"@id":"https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/#primaryimage"},"thumbnailUrl":"https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-scaled.jpg","articleSection":["Reference"],"inLanguage":"pl-PL","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/","url":"https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/","name":"Ucieczka termiczna w bateriach litowo-jonowych - Metis Engineering","isPartOf":{"@id":"https:\/\/metisengineering.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/#primaryimage"},"image":{"@id":"https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/#primaryimage"},"thumbnailUrl":"https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-scaled.jpg","datePublished":"2025-08-12T06:45:53+00:00","dateModified":"2025-12-18T06:34:37+00:00","description":"Wczesne wykrywanie niekontrolowanego wzrostu temperatury w akumulatorach litowo-jonowych za pomoc\u0105 czujnika Cell Guard firmy Metis Engineering Niekontrolowany wzrost temperatury (TR) jest jednym z najbardziej krytycznych zjawisk w akumulatorach litowo-jonowych.","inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/metisengineering.com\/thermal-runaway-in-lithium-ion-batteries\/#primaryimage","url":"https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-scaled.jpg","contentUrl":"https:\/\/metisengineering.com\/wp-content\/uploads\/2025\/08\/METIS_MAY_2023_004-scaled.jpg","width":2560,"height":1782,"caption":"Battery destruction. 22 May 2023"},{"@type":"WebSite","@id":"https:\/\/metisengineering.com\/#website","url":"https:\/\/metisengineering.com\/","name":"Metis Engineering","description":"Wyczuwanie przysz\u0142o\u015bci","publisher":{"@id":"https:\/\/metisengineering.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/metisengineering.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/metisengineering.com\/#organization","name":"Metis Engineering","url":"https:\/\/metisengineering.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/metisengineering.com\/#\/schema\/logo\/image\/","url":"https:\/\/metisengineering.com\/wp-content\/uploads\/2024\/06\/metis-logo-240.png","contentUrl":"https:\/\/metisengineering.com\/wp-content\/uploads\/2024\/06\/metis-logo-240.png","width":240,"height":95,"caption":"Metis Engineering"},"image":{"@id":"https:\/\/metisengineering.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/metisengineering.com\/#\/schema\/person\/6b885e54b520c8d41752069c93f067ae","name":"\u0141ukasz","image":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/secure.gravatar.com\/avatar\/55d18e132c3d0d63f7cd047da2d2a7f805a3392a84a615be5d6dca867281758e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/55d18e132c3d0d63f7cd047da2d2a7f805a3392a84a615be5d6dca867281758e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/55d18e132c3d0d63f7cd047da2d2a7f805a3392a84a615be5d6dca867281758e?s=96&d=mm&r=g","caption":"Lukasz"}}]}},"_links":{"self":[{"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/posts\/3507","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/comments?post=3507"}],"version-history":[{"count":5,"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/posts\/3507\/revisions"}],"predecessor-version":[{"id":3537,"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/posts\/3507\/revisions\/3537"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/media\/3534"}],"wp:attachment":[{"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/media?parent=3507"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/categories?post=3507"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/metisengineering.com\/pl\/wp-json\/wp\/v2\/tags?post=3507"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}